Primary Application*
Frequency*
Length of Cable Assembly*
Configure using

Selecting TRU standard specifications will default the final performance summary review to the specifications associated with the TRU product selected during the configuration process.

Specify Electrical, Mechanical or Environmental Specs for Assembly

Electrical
or VSWR  
(dB)

in Watts, Average

Mechanical
Environmental Conditions

feet
Series
Gender
Available Connectors (32)

  Interface Gender Type Maximum Frequency Power Handling @ max freq (Watts) Insertion Loss (dB)
2.4 mm
Male Straight 50 GHz 10 0.21
2.9 mm
Male Straight 46 GHz 15 0.20
3.5 mm
Male Straight 36 GHz 20 0.18
SMA
Male Straight 26 GHz 50 0.15
N
Male Straight 18 GHz 220 0.13
N
Male Right Angle 18 GHz 220 0.21
ATNC
Male Straight 18 GHz 150 0.13
TNC
Male Straight 15 GHz 250 0.12
SC
Female Straight 10 GHz 550 0.09
SC
Male Straight 10 GHz 550 0.09
C
Male Right Angle 10 GHz 550 0.16
C
Male Straight 10 GHz 550 0.09
7-16
Male Right Angle 7 GHz 0.14
7-16
Male Straight 7 GHz 0.08
EIA 7/8
Male Straight 6 GHz 840 0.07
EIA 7/8
Female Straight 6 GHz 840 0.07
MEIA™-875
Male Straight 6 GHz 840 0.07
QDS
Male Straight 6 GHz 1700 0.07
QDS
Male Right Angle 6 GHz 1700 0.12
HN
Male Right Angle 4 GHz 576 0.10
HN
Male Straight 4 GHz 576 0.06
EIA 1-5/8
Female Straight 3 GHz 0.05
EIA 1-5/8
Male Straight 3 GHz 0.05
MEIA™-1625
Male Straight 3 GHz 0.05
QRM™
Male Straight 1 GHz 2200 0.03
QRM™
Male Right Angle 1 GHz 2200 0.05
LC
Male Straight 1 GHz 2500 0.03
LC
Male Right Angle 1 GHz 2500 0.05
SQS™
Male Straight 500 MHz 7500 0.02
SQS™
Male Right Angle 500 MHz 7500 0.04

Choose your cable. Need to compare cable attributes?

Available Cables (12)
  Cable Name Max Freq (GHz) Mas Attenuation (dB/FT) @Fmax VP Nominal(%) Shielding Effectiveness Min. (dB) OD (inches) Max Temp.(°C) Power Handling @Fmax (Watts) Insertion Loss/ft (dB) Min. Bend Radius
TRU RG-217 3 GHz 0.107 66% 60 0.545 85 2.75" (static)
TRU RG-214 3 GHz 0.15 66% 60 0.425 85 2.25" (static)
TRU RG-393 6 GHz 0.220 70% 60 0.390 200 530 0.27 N/A
TRU-560 6 GHz 0.095 77% 75 0.565 105 2936 0.10 1.70" (static), 2.80" (dynamic)
TRU-500 6 GHz 0.095 77% 75 0.490 200 2936 0.10 1.50" (static), 2.45" (dynamic)
TRU-450 10 GHz 0.133 83% 90 0.450 200 1.50" (static), 2.50" (dynamic)
TRU-350 18 GHz 0.260 83% 90 0.335 200 439 0.26 1.00" (static), 1.70" (dynamic)
TRU-300 18 GHz 0.284 78% 90 0.300 200 800 0.28 0.90" (static), 1.50" (dynamic)
TRU-TEST 18 GHz 0.400 80% 90 0.195 200 172 0.40 0.60" (static), 1.00" (dynamic)
TRU-210 26 GHz 0.523 78% 90 0.208 200 360 0.53 0.60" (static), 1.00" (dynamic)
TRU-160 40 GHz 0.9733 78% 90 0.160 200 150 0.85 0.48" (static), 0.80" (dynamic)
TRU-120 50 GHz 1.440 78% 90 0.122 200 1.45 0.38" (static), 0.60" (dynamic)
Series
Gender
Available Connectors (32)

  Interface Gender Type Maximum Frequency Power Handling @ max freq (Watts) Insertion Loss (dB)
2.4 mm
Male Straight 50 GHz 10 0.21
2.9 mm
Male Straight 46 GHz 15 0.20
3.5 mm
Male Straight 36 GHz 20 0.18
SMA
Male Straight 26 GHz 50 0.15
N
Male Straight 18 GHz 220 0.13
N
Male Right Angle 18 GHz 220 0.21
ATNC
Male Straight 18 GHz 150 0.13
TNC
Male Straight 15 GHz 250 0.12
SC
Female Straight 10 GHz 550 0.09
SC
Male Straight 10 GHz 550 0.09
C
Male Right Angle 10 GHz 550 0.16
C
Male Straight 10 GHz 550 0.09
7-16
Male Right Angle 7 GHz 0.14
7-16
Male Straight 7 GHz 0.08
EIA 7/8
Male Straight 6 GHz 840 0.07
EIA 7/8
Female Straight 6 GHz 840 0.07
MEIA™-875
Male Straight 6 GHz 840 0.07
QDS
Male Straight 6 GHz 1700 0.07
QDS
Male Right Angle 6 GHz 1700 0.12
HN
Male Right Angle 4 GHz 576 0.10
HN
Male Straight 4 GHz 576 0.06
EIA 1-5/8
Female Straight 3 GHz 0.05
EIA 1-5/8
Male Straight 3 GHz 0.05
MEIA™-1625
Male Straight 3 GHz 0.05
QRM™
Male Straight 1 GHz 2200 0.03
QRM™
Male Right Angle 1 GHz 2200 0.05
LC
Male Straight 1 GHz 2500 0.03
LC
Male Right Angle 1 GHz 2500 0.05
SQS™
Male Straight 500 MHz 7500 0.02
SQS™
Male Right Angle 500 MHz 7500 0.04
Details
Connector A
Cable
Connector B
Length
Operating Temperature
Operating Altitude
Mechanical Conditions
Environmental Conditions
Minimum Bend Radius
Drawing
  1. Heat shrink strain relief (1 each end, not shown above)
  2. Wrap around marker label (1 each end, not shown above) TRU P/N & date code
  3. Unless otherwise specified, all connectors are clamp attachment

Performance Analysis
Your Requirements
Cable Assembly Specifications (calculated)
Frequency Range of Assembly 1 2 2
Max Return Loss (or VSWR)
Min Shielding Effectiveness (dB)
Power Handling (watts) TRU Standard TRU Standard
Total Attenuation/Insertion Loss (dB) TRU Standard TRU Standard
Please Specify any Additional Requirements

Save your Assembly

To save a paper copy of your assembly, click below.



To email copy of your assembly, please enter your email.

Request a quote

Please provide your contact information.


Thank you for your submission.

There was an error sending your quote request. Please try again. If the problem persists, please contact us.

First Name:*
 
Last Name:*
 
Position/Title:
Company:*
Phone Number:*
Email Address:*
Street Address:*
City/Town:*
State:*
Zip Code:*
Country:*
Quantity Requested:
Comments: